Technical Data
Construction The CF200 fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durability and appearance. Fitted with a powerful backward curved centrifugal impeller. A spring operated non return flap is built into the discharge spigot to prevent backdraughts. Electrical 220-240V ~ A.C. 50Hz ns . Single phase consuming 45 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan should not be accessible to a person using either the shower or the bath and mounted a minimum of 1.8 metres from the floor. Motor Single phase induction motors with pre-oiled bearings fitted for a long maintenance free life and protected by an auto-reset thermal cut-out. Guarantee Two year no quibble guarantee. Installation All models are designed to be mounted on walls or ceilings and discharged through 100mm (4") diameter flexible or rigid pipes. Also suitable for use with the Manrose low profile flat channel ducting systems 100mm or 125mm ranges. Performance 110m³hr, 31 litres per second. Packaging Boxed in cartons of 10 measuring 753mm x 283mm x 390mm and weighs 12kgs. Additional Data Maximum pressure: 120 p.a. Fan speed: 1400 r.p.m. Sound volume: 45.0 dB(A). Back to the top |
||||||||||||||||||
|
1 Albion Close, Slough, Berkshire, SL2 5DT Tel: 01753 691399, Fax: 01753 692294, email: sales@manrose.com |