Technical Data
Construction These fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durability and appearance. Electrical 220-240V ~ A.C. 50Hz ns. Single phase consuming 25 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or the bath and mounted a minimum of 1.8 metres from floor. Motor Single phase induction motors with pre-oiled bearings fitted for a long maintenance free life and protected by a thermal fuse. Guarantee Two year no quibble guarantee. Installation XF120 Series designed to be mounted on walls or ceilings (pullcord models wall mounting only) through 120mm (5") diameter flexible or rigid pipes. Also suitable for use with the Manrose low profile flat channel ducting systems. XP120 Series designed for through wall fixing and comes complete with aluminium flexible ducting and external wall grille. WF120 Series designed for window mounting through a standard 140mm - 155mm Ø hole. Performance The extract rate of all models is 130m³hr, 36 litres per second. Packaging XF120 Series in outers of 10 measuring 400mm x 215mm x 490mm and weighs 8 kgs. XP120 Series in outers of 10 measuring 398mm x 210mm x 825mm and weighs 10 kgs. WF120 Series in outers of 10 measuring 446mm x 225mm x 550mm and weighs 10 kgs. Additional Data Maximum pressure: 35 p.a. Fan speed: 2000 r.p.m. Sound volume: 41.0 dB(A) Maximum operating temperature 400C. Back to the top |
||||||||||||||||||||||||||
|
1 Albion Close, Slough, Berkshire, SL2 5DT Tel: 01753 691399, Fax: 01753 692294, email: sales@manrose.com |